ROBOTAPE 50 CFA
TAPE CLOSING OR
DESCENDING BRIDGE
PHOTOCELL ALARMS
ENGAGED
T
he tape closur
e
or bridge
descending
photocell is
engaged
immediately after
the bridge rises
up again and the
belts are
reopened.
Red light: 1
flash.
- Remove any
products found in
front of the
photocells.
- Press the "Start"
button.
PRODUCT TRANSIT
WARNING
A product is
taking too long
to be taped.
Red light: 2
flashes.
- Press the "STOP"
button.
- Remove the
product.
- Press the "Start"
button.
BRIDGE NOT UP
WARNING
T
he bridge can’
t
reach the upward
position.
Red light: 3
flashes.
- Check the
pressure in the
pneumatic system.
- Press the "Start"
button.
TAPES NOT OPEN
WARNING
T
he tapes are no
t
opening.
Red light: 4
flashes.
- Check the
pressure in the
pneumatic system.
- Press the "Start"
button.
BRIDGE NOT DOWN
WARNING
T
he bridge can’
t
reach the
downward
position.
Red light: 5
flashes.
- Press the "STOP"
button.
- Check the
pressure in the
pneumatic system.
- Press the "Start"
button.
FLAP COVER
PHOTOCELL ALARM
ENGAGED
T
he flap closur
e
photocell doesn’t
free itself
during the taping
of the product.
Red light: 6
flashes.
- Press the "STOP"
button.
- Remove the
products.
Press the "Start"
button -.
ENTRANCE
PHOTOCELL ALARM
ENGAGED
T
he flap closur
e
photocell or the
entrance
photocell are
engaged for too
long while
waiting for
products: a
product may be
stuck in the
entrance.
Red light: 7
flashes.
- Press the "STOP"
button.
- Remove the
products.
- Press the "Start"
button.
8.3. MESSAGES
| Note
These messages do not stop the machine.
English
52/75