8. TROUBLESHOOTING
8.1. TROUBLES, CAUSES AND REMEDIES
The troubleshooting table lists the problems, the possible causes and solutions.
Problem Cause Remedy
The box blocks during the
taping operation.
Conveying belts worn out. Replace conveying belts.
See “conveyor belt
replacement”.
The closing tape is not
centred on the box.
he transmission chain of
the transport unit moves
too slow.
Adjust the tension of the
driving chain.
See “how the adjust the
driving chain of the
transport unit”.
|
Important
For inconveniences, causes and remedies relating to the taping unit, consult the proper instructions manual
T50 - T75 - T50/30 (See "how to correct the ta
in
defects").
8.2. ALARM MESSAGES
In case of breakdowns or malfunctionin
durin
rocessin
the machine sto
s automaticall
.
|
Important
For these operations a precise technical skill or ability is required; therefore, these operations must be
exclusively performed by qualified personnel with certified experience acquired in the specific field.
Warning Cause Signalling on
column
Remedy
EMERGENCY ALARM
MUSHROOM BUTTON
PRESSED
Emergency alarm
mushroom button
pressed.
Red light:
constantly on.
- Reset the
emergency stop
button.
- Press the "Start"
button.
GUARD WARNING Guards open. Red light:
constantly on.
- Close the guards.
- Press the "Start"
button.
THERMAL
PROTECTION ALARM
hermal or
magneto - thermal
relay protection.
Red light:
constantly on.
- Eliminate the
overload cause,
reset guards with
the specific reset.
- Press the "Start"
button.
LACK OF/END OF
TAPE ALARM
he tape i
either broken or
finished.
Red light:
continuous
flashing.
- Insert the tape
or replace the
coil.
- Press the "Start"
button.
English