Controller Functionality
Tab le 2 describes functionality available with CompactLogix 5370 controllers.
Table 2 - CompactLogix 5370 Controller Functionality
Cat. No. Controller
Tasks
Supported
Programs
Supported Per
Task
Internal Energy
Storage Solution
EtherNet/IP
Network
Topology
Support
Power Supply
Distance Rating
Onboard User
Memory Size
Local I/O
Module Support
1769-L16ER-BB1B 32 1000 Yes - Eliminating
the need for a
battery
Support the
following
topologies:
• Device Level
Ring (DLR)
•Linear
• Traditional star
NA 384 KB As many as six
1734 POINT I/O
modules
(3)
1769-L18ER-BB1B 512 KB As many as eight
1734 POINT I/O
modules
(3)
1769-L18ERM-BB1B
1769-L19ER-BB1B 1 MB
1769-L24ER-QB1B See footnote
(2)
768 KB As many as four
Compact I/O
modules
1769-L24ER-QBFC1B
1769-L27ERM-QBFC1B 1 MB
1769-L30ER 4 1 MB As many as eight
Compact I/O
modules
1769-L30ER-NSE
1769-L30ERM
1769-L33ER 2 MB As many as 16
Compact I/O
modules
1769-L33ERM
1769-L33ERMO —
1769-L36ERM 3 MB As many as 30
Compact I/O
modules
1769-L36ERMO —
1769-L37ERM, 1769-L37ERMK 4MB
1769-L37ERMO
(1)
1769-L38ERM, 1769-L38ERMK 5MB
1769-L38ERMO
(1)
(1) Available at software version 31 and firmware revision 31.
(2) CompactLogix 5370 L2 controllers have an embedded power supply. Therefore, you do not need to consider power supply distance rating when installing the controller. The Compact I/O modules that
are used as local expansion modules in a CompactLogix 5370 L2 control systems operate on a CompactBus. These Compact I/O modules also have a power supply distance rating that you must consider
when installing those modules.
For more information on power supply distance rating regarding how to use Compact I/O modules in a CompactLogix 5370 L2 control system, see page 123
and page 220.
(3) IMPORTANT: You can use up to the maximum number of 1734 POINT I/O modules with the CompactLogix 5370 L1 controllers that are listed in Tab le 3
. This applies only as long as the total current that
the modules draw does not exceed the available POINTBusâ„¢ backplane current of 1 A. If you must use more local expansion modules than the POINTBus backplane current supports, you can install a
1734-EP24DC POINT I/O expansion power supply between local expansion modules to increase the POINTBus backplane power and meet your system requirements.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley 1769-L24ER-QBFC1B and is the answer not in the manual?

Rockwell Automation Allen-Bradley 1769-L24ER-QBFC1B Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley 1769-L24ER-QBFC1B
CategoryController
LanguageEnglish

Related product manuals