Rockwell Automation Publication 1426-UM001J-EN-P - August 2019 377
PowerMonitor 5000 Unit Data Tables Appendix A
17 Real 200mS_L1_kW L1 real power kW -9.999E15…
9.999E15
18 Real 200mS_L2_kW L2 real power kW -9.999E15…
9.999E15
19 Real 200mS_L3_kW L3 real power kW -9.999E15…
9.999E15
20 Real 200mS_Total_kW Total real power kW -9.999E15…
9.999E15
21 Real 200mS_L1_kVAR L1 reactive power kVAR -9.999E15…
9.999E15
22 Real 200mS_L2_ kVAR L2 reactive power kVAR -9.999E15…
9.999E15
23 Real 200mS_L3_ kVAR L3 reactive power kVAR -9.999E15…
9.999E15
24 Real 200mS_Total_ kVAR Total reactive power kVAR -9.999E15…
9.999E15
25 Real 200mS_L1_kVA L1 apparent power kVA 0…9.999E15
26 Real 200mS_L2_ kVA L2 apparent power kVA 0…9.999E15
27 Real 200mS_L3_ kVA L3 apparent power kVA 0…9.999E15
28 Real 200mS_Total_ kVA Total apparent power kVA 0…9.999E15
29 Real 200mS_L1_True_PF L1 true power factor (full bandwidth) % 0.00…100.00
30 Real 200mS_L2_True_PF L2 true power factor (full bandwidth) % 0.00…100.00
31 Real 200mS_L3_True_PF L3 true power factor (full bandwidth) % 0.00…100.00
32 Real 200mS_Total_True_PF Average true power factor % 0.00…100.00
33 Real 200mS_L1_Disp_PF L1 displacement power factor (fundamental only) % 0.00…100.00
34 Real 200mS_L2_Disp_PF L2 displacement power factor (fundamental only) % 0.00…100.00
35 Real 200mS_L3_Disp_PF L3 displacement power factor (fundamental only) % 0.00…100.00
36 Real 200mS_Total_Disp_PF Average displacement power factor (fundamental only) % 0.00…100.00
37 Real 200mS_L1_PF_LeadLag_Indicator L1 lead or lag indicator for power factor 1 = leading,
-1 = lagging.
--11
38 Real 200mS_L2_PF_LeadLag_Indicator L2 lead or lag indicator for power factor 1 = leading,
-1 = lagging.
--11
39 Real 200mS_L3_PF_LeadLag_Indicator L3 lead or lag indicator for power factor 1 = leading,
-1 = lagging.
--11
40 Real 200mS_Total_PF_LeadLag_Indicator Total lead or lag indicator for power factor 1 = leading,
-1 = lagging
--11
41 Real 200mS_Sag_Swell_Status_Flag A flag indicating 200 ms result has been calculated during
a Sag, Swell, or Interruption.
#01
42 Real 200mS_Metering_Iteration A number 0…9,999,999 that indicates that the metering
functions and internal communications are updating.
# 9,999,999