EasyManua.ls Logo

Rohde & Schwarz FSW Series - Page 151

Rohde & Schwarz FSW Series
371 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Analysis
R&S
®
FSW-K7
151User Manual 1173.9240.02 ─ 17
Name...........................................................................................................................151
Comment.....................................................................................................................151
Threshold.................................................................................................................... 151
Margin......................................................................................................................... 152
X-Axis..........................................................................................................................152
Y-Axis..........................................................................................................................152
Data points..................................................................................................................152
Insert Value.................................................................................................................153
Delete Value................................................................................................................153
Shift x.......................................................................................................................... 153
Shift y.......................................................................................................................... 153
Save............................................................................................................................153
Name
Defines the limit line name. All names must be compatible with Windows conventions
for file names. The limit line data is stored under this name (with a .LIN extension).
Remote command:
CALCulate:LIMit<k>:NAME on page 326
Comment
Defines an optional comment for the limit line. The text may contain up to 40 charac-
ters.
Remote command:
CALCulate:LIMit:COMMent on page 322
Threshold
Defines an absolute threshold value (only for relative scaling of the y-axis).
Remote command:
CALCulate:LIMit<k>:LOWer:THReshold on page 326