SNMP System Monitoring
R&S VENICE S
SNMP naming and OID structure
The following values are possible for each of the variables:
● Channel: 1-4, 11-14
- Note: 11-14 means channel 1 to 4 on card 2. Also, index is only used
when [Card] is not used
● Card: 1, 2
● Stream:
- for video: 0
- for ANC: 0
- for audio: 0-15 (1-16 in the object ID)
● Storage (A/B): A or B (A and B being redundant storage systems)
Basic System Monitoring via SNMP
SNMP allows you to monitor and query the state of several basic R&S
VENICE hardware components in a network such as:
● Fans
● Disks arrays
● Power supply units
● CPU
To query information of non-SSFS internal R&S VENICE storages use the
following SNMP data points:
● HOST-RESOURCES-MIB: data point: hrStorageTable
● UCD-SNMP-MIB: data point dskTable
External SSFS storage information cannot by queried directly via SNMP
from R&S VENICE S. If R&S VENICE S is connected to a SpycerNode
system, the mounted SSFS storage information can be queried from the
following SpycerNode SNMP data points:
● GPFS-MIB: gpfsFileSystemStatusTable