Product Description
Network Ports
R&S VENICE S
66
User Manual | 2906.2506.02 - 01
VENICE S Client Ports (Information)
8031 primary
(eno8303)
http no
13217 primary
(eno8303)
propri-
etary
no
Port NIC Multicast Protocol Configurable Config recom-
mended
Port Type Direction Info Remarks
3702 UDP out WSDD service discovery udp multicast to/from ip
239.255.255.250:
443 TCP out Device Manager using VENICE tcp / https
service:
Accessing standard web
server for browser based
configuration tool "Device
Manager".
If accessing via insecure port
80, users are redirectes to port
443 using secure http connec-
tion.
8070 UDP in Maintenance service using VENICE tcp / https
service:
This interface controls overall
VENICE server configuration
and options.
8011 – 8014,
8019,
8021 – 8024,
8029
TCP in VENICE web service, FIMS,
MOS
using VENICE tcp/http service:
The per-channel VENICE web
services, offering control over
the video server via the MOS
and FIMS standards.
30001 UDP in & out SpycerNet service discovery udp multicast to/from
239.255.0.1:
This port is used to find other
spycer service for interopera-
tion in the spycer network.