Installation and Configuration
77
User Manual | 2906.2506.02 - 01
Configuring the System
R&S VENICE S
Configuring the System
For the initial setup the device must be integrated into a network.
Network Configuration
There are two ways for the network configuration. You can use a dynamic or
a static IP address as described bellow. We recommend to use a static IP for
the initial setup.
Using a Static IP
Perform the following steps:
1. Connect your laptop or PC directly to network interface “eno8403“, see
Network Interface (NIC) Connectors (page 49)
2. Configure your PC‘s/laptops network interface to a static IP address
10.0.0.8.
3. Open a SSH console to the IP 10.0.0.8.
Alternatively you can use a local console with keyboard/mouse.
4. Log in as root with the following password: [serial number of the
device].
5. Edit the configuration file with:
vi /etc/sysconfig/network-scripts/ifcfg-eno8403
6. Change line IPADDR=10.0.0.8 into: IPADDR= your new IP address
7. Activate the new IP with:
systemctl restart network
Now R&S VENICE S is ready for integrating the software services.
Using a Dynamic IP
Perform the following steps:
1. Connect a cable from the network interface “eno8303“.
2. Determine the dynamic IP address with the command:
ifconfig eno8303
Now the dynamic IP address can be used for further configurations.