Integrating Software Service
This setting configures which network interface the software uses for
communication. In general this setting is already configured to use the inter-
face “eno8303“. Only use the following steps if a different configuration is
necessary.
Perform the following steps:
• Use the command fbms-setup.sh -c [interface] to integrate the
software services on the network.
e.g.: fbms-setup.sh -c eno8403 (It‘s the most common use to change
to port “eno8403“ for static IP setups.)
After the command is executed the configuration is complete. R&S
VENICE S can immediately be operated by remote control from any
Windows system connected to the same network.
System Update
There is a factory created base image on the system disks that does not
contain the latest VENICE software.
Perform the following steps:
• Follow the steps in chapter “System Update” on page 105.
You are in full operating state now and can configure the R&S VENICE S
and change it’s operating modes (VDCP, MOS, FIMS) to demo all function-
ality with the available graphical clients.
Management Tool R&S®Device Manager
As soon as you have the network up and running you can access the
R&S
®
Device Manager from your PC/laptop for all kind of configuration and
management. To get access to the R&S
®
Device Manager you have to enter
the previously determined IP address in a standard browser (see chapter
“Network Configuration” on page 77).