Troubleshooting
Troubleshooting Power Supply Units
R&S VENICE S
174
User Manual | 2906.2506.02 - 01
Troubleshooting Power Supply Units
Troubleshooting Power Source Problems
Perform the following steps:
1.
Press the power button to ensure that your system is turned on. If the
power indicator does not glow when the power button is pressed, press
the power button firmly.
2. Plug in another working power supply unit to ensure that the system
board is not faulty.
3. Ensure that no loose connections exist.
For example, loose power cables.
4. Ensure that the power source meets applicable standards.
5. Ensure that there are no short circuits.
6. Have a qualified electrician check the line voltage to ensure that it meets
the needed specifications.
Power Supply Unit Problems
Perform the following steps:
1. Ensure that no loose connections exist.
For example, loose power cables.
2. Ensure that the power supply handle/LED indicates that the power
supply is working properly.
3. If you have recently upgraded your system, ensure that the power supply
unit has enough power to support the new system.
4. If you have a redundant power supply configuration, ensure that both the
power supply units are of the same type and wattage.
If the LED You may have to upgrade to a higher wattage power supply
unit.
5. Ensure that you use only power supply units with the Extended Power
Performance (EPP) label on the back.
6. Reseat the power supply unit.
NOTE: After installing a power supply unit, allow several
seconds for the system to recognize the power supply unit and
determine if it is working properly.
If the problem persists, contact your local vendor or Rohde & Schwarz
directly.