Troubleshooting
177
User Manual | 2906.2506.02 - 01
Restarting a Single Channel
R&S VENICE S
Restarting a Single Channel
Currently, restarting a single VENICE channel is possible only via terminal.
This section describes the procedure of restarting a single channel without
having to restart the rest of the adjacent channels.
Perform the following steps:
1.
If using a Windows system, make sure a SSH client (e.g PuTTY) is
installed which will allow you to access a remote Linux based VENICE
system.
2. In the command prompt, log in to the VENICE server.
After login the command prompt should look like this:
root@[name-of-the-system]
3. Stop the desired channel with /opt/rohde-schwarz/venice stop
[channel number].
4. Start the channel again with /opt/rohde-schwarz/venice start
[channel number].
Systems built
before 2020
USERNAME: root
PASSWORD: password
Systems built
after 2020
USERNAME: root
PASSWORD: [serial number of the device].
The error message "Failed to load device config" is not relevant in that case
and can be ignored.