Administration
Integration into an IP Network
R&S VENICE S
124
User Manual | 2906.2506.02 - 01
Activating the SMPTE 2110 IP Interfaces
Perform the following steps:
1.
Open the R&S®Device Manager as described in "Configuring the IP
interfaces" (page 120) and select the corresponding video server.
2. Navigate to System > Network interface settings.
3. Switch INTERFACE STATUS to ON for all required interfaces, see also
"Preconditions" (page 119) for the required interfaces.
4. Configure static or DHCP settings.
5. Press Apply to confirm your settings.
6. Each time you change the network settings the network service is
restarted on the associated device. Press OK to confirm the warning
message.