Administration
127
User Manual | 2906.2506.02 - 01
Integration into an IP Network
R&S VENICE S
2.
Set R&S VENICE S to PTP clock synchronization mode with the
VeniceWS SOAP request configureSyncRequest. Send the following
request to [Management-IP]:8011 and [Management-IP]:8021:
Configuring the PTP Parameters
Perform the following steps:
1. Open the R&S®Device Manager as described in "Configuring the IP
interfaces" (page 120) and select the corresponding video server.
2. Navigate to Services > PTP settings.
3. Determine the defaults for your specific PTP environment.
4. Press Apply to confirm your settings.
<soapenv:Envelope
xmlns:soapenv="http://schemas.xmlsoap.org/soap/envelope/"
xmlns:urn="urn:rus:webservices:venice">
<soapenv:Header/>
<soapenv:Body>
<urn:configureSyncRequest>
<urn:syncConfiguration>
<!--Optional:-->
<urn:syncMode>PTP</urn:syncMode>
<urn:syncHPhase>0</urn:syncHPhase>
<urn:syncVPhase>0</urn:syncVPhase>
</urn:syncConfiguration>
<!--Optional:-->
</urn:configureSyncRequest>
</soapenv:Body>
</soapenv:Envelope>
Both interfaces rsipXs1 and rsipXs0 of the corresponding card X need to be
enabled even if only one interface is connected to the network. Otherwise
PTP will not work correctly after reboot. See also "Activating the SMPTE 2110
IP Interfaces" (page 124) for activation instructions.
This panel also contains PTP status monitoring information for one card of
R&S VENICE S4 and two cards of R&S VENICE S8.