EasyManua.ls Logo

Rohde & Schwarz R&S VENICE S800/824-G3 - Page 126

Rohde & Schwarz R&S VENICE S800/824-G3
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Administration
Integration into an IP Network
R&S VENICE S
126
User Manual | 2906.2506.02 - 01
5.
Select SYNC CONFIGURATION and set SYNC MODE to PTP.
6. Repeat steps 4 and 5 with CURRENT CHANNEL being set to 11.
7. Press Apply to confirm your settings.
Using the R&S
VENICE Web
Service
(VeniceWS)
Perform the following steps:
1. Use the VeniceWS SOAP request querySyncConfigurationRequest
to check if R&S VENICE S uses PTP synchronization mode. Send the
following command to [Management-IP]:8011 and [Management-
IP]:8021:
<soapenv:Envelope
xmlns:soapenv="http://schemas.xmlsoap.org/soap/envelope/"
xmlns:urn="urn:rus:webservices:venice">
<soapenv:Header/>
<soapenv:Body>
<urn:querySyncConfigurationRequest/>
</soapenv:Body>
</soapenv:Envelope>

Table of Contents