Chapter 5 Operation
5300.9677.71 - 5.27 - EN-4
2.3 Operation Menu Window
You can use the Operation menu window to enter settings for standby behavior and for the
exciter and amplifier.
Display Explanation
Operation Mode Status of transmission operation
Input Ok: All activated inputs are OK.
W: At least one activated input is not OK.
Forward Power Ok: Transmitted power is OK.
W: Transmitted power is not OK.
Exc Warn There is an exciter sum warning.
Ost Sum Warn There is an output stage sum warning.
Temperature Ok: Device temperature is OK.
W: Device temperature is not OK.
Local Mode Gray: Remote operation; the transmitter parameters can only be
changed via remote control.
On: Local operation; the transmitter parameters can only be changed
locally.
Interlock Gray: RF interlock loop closed
On: RF interlock loop not closed
VSWR Status of the VSWR
Exc Fail There is an exciter sum fault.
Ost Sum Fault There is an output stage sum fault.
Fans Ok: Fans are OK.
W: At least one fan is faulty.