Chapter 8 Service
5300.9677.72 - 8.7 - EN-4
Fig. 2 Removing connector of faulty fan
3. Unscrew the fuse block (if fitted) using a Torx screwdriver (size 10).
4. Slide the faulty fan upward and pull the fan out.
5. Pull the fan shroud off the removed fan.
The fan shroud is not changed; it is fitted to the replacement fan.
3.1.2 R&S SR8025/SR8050/SR8100/SR8130/VU813
1. Cut through the cable tie securing the two fan cables.
2. Press the catch (X31: at top; X32: at bottom) on the connector of the faulty fan and dis-
connect the connector.