EasyManua.ls Logo

Rohde & Schwarz SR8000 Series - Exciter > Input > Automatic Input Menu Window

Rohde & Schwarz SR8000 Series
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Operation
5300.9677.71 - 5.51 - EN-4
The settings can be made separately for each of the three data inputs.
Note The AUX inputs AUX1 and AUX2 have the same priority and identical characteristics. Typ-
ically, the RDS signal is fed in at AUX1. AUX3 is only available internally in the transmitter.
2.7.2.4 Exciter > Input > Automatic Input Menu Window
In the Automatic Input menu window, you can select parameters for the current AF input
for the stereo coder.
Display/entry Explanation
AUX1 to AUX3
Level For setting the nominal input amplitude
Value range: -18 dBu to -7 dBu (default setting -14 dBu)
Deviation For setting the frequency deviation caused by the nominal input
level
Value range: 2 kHz to 10 kHz (default setting 4 kHz)
Active For activating the corresponding input
Selection: ON/OFF
Threshold For setting the input amplitude threshold for monitoring
Percentage value range: 2% to 80% (default setting 5%)
Absolute value range in dBu (the system uses the percentage
value; the absolute value is converted into the corresponding,
rounded-off percentage value)
On-Time If the input amplitude is continuously above the threshold during the
set On-Time, the input is considered to be OK.
Value range: 1 s to 6000 s (default setting 5 s)
Off-Time If the input amplitude is continuously below the threshold during the
set Off-Time, the input is considered not to be OK.
Value range: 1 s to 6000 s (default setting 5 s)

Table of Contents

Related product manuals