2.5.5.3 Setup > SNMP > Alarmsinks Menu Window
You can use the Alarmsinks menu window to configure alarm sinks.
Community [1 … 5] Used to set the SNMP community string (a type of password) for a user
group
Default setting: "public" for read only (GET) and "broadcast" for read /
write (SET)
Case-sensitive!
Enable Used to activate (On) or deactivate (Off) a community
The Off setting is used for configuration purposes and for testing.
Function Description
Alarmsink Used to select one of 5 alarm sinks for configuration
Enable Used to activate (On) or deactivate (Off) a selected alarm sink
The Off setting is used for configuration purposes and for testing.
IP Address IP address of the alarm sink to which alarms are to be sent
Port UDP port for the SNMP alarms
Default setting: 162
Alarm Version SNMP version in which the alarm is to be sent (v1 Trap or v2c Trap)
Traps are transmitted once only.
Community Used to select the community (access protection)
The community set here must also be used on the manager side. A dis-
tinction is made between upper-case and lower-case characters.
Communities are configured in the SNMP > Manager menu.