Chapter 4 Putting into Operation
5300.9677.72 - 4.26 - EN-4
4 R&S NetCCU800 Setup for 1+1/N+1 Systems
with R&S SR8000
) Check the settings in the following menus of the R&S NetCCU800 Switchover Unit
(NSU):
Switch over Unit > Setup > TX Setup > TX Ai (i = 1 to 8 according to the number of
transmitters)
Switch over Unit > Setup > TX Setup > TX B
The correct settings for a type R&S SR8000 transmitter are as follows:
Note If the setting for Model is changed, it is then necessary to correct the setting for with
NetCCU800.
IP addresses of operational and standby transmitters
If you make use of the option under Setup > System in the R&S SR8000 menu to set the
Tx Mode to 1+1 or N+1, the IP address of the hindmost Ethernet interface is fixed in accor-
dance with the Tx Reserve parameter:
) Please make sure that the same value is used for the IP address of the transmitter con-
cerned in the NSU menus ... > Tx Setup > Tx Ai and ... > Tx Setup > Tx B.
Model Low power EXC
Type Single Tx
with NetCCU800 No
with DVB receiver No
Tx Reserve Fixed IP address
A1 192.168.59.241
A2 192.168.59.242
A3 192.168.59.243
A4 192.168.59.244
A5 192.168.59.245
A6 192.168.59.246
A7 192.168.59.247
A8 192.168.59.248
B 192.168.59.249