Chapter 5 Operation
5300.9677.71 - 5.31 - EN-4
2.5.2 Setup > System Menu Window
In the System menu window, you can configure an existing standby system and the parallel
remote-control interface.
In the case of the R&S SR8130 base unit, you can also choose whether you intend the sys-
tem to be operated with or without a separate amplifier.
2.5.3 Setup > Ethernet Menu Window
You can use the Ethernet menu window to make the settings necessary for connecting the
transmitter in the following ways:
Selection Description
Transmitter ID User-definable ID (e.g. name) of the transmitter
Model Must be set to Transmitter
Tx Mode Used to set a standby system (if available):
a)
Standalone (single transmitter)
1+1 (1+1 standby system)
n+1 (n+1 standby system)
a) With 1+1 and n+1 systems, the IP address of the rear Ethernet interface is set to a fixed value.
Tx Reserve A1 to A8, B (used to select the transmitter number in a 1+1 or n+1
standby system)
Parallel IO Used to activate/deactivate the parallel remote-control interface of the
transmitter
ParIO Inhibit Status For local mode, the messages from the parallel remote-control interface
of the transmitter are activated/deactivated
Additional Amplifier Operation with/without separate R&S VU813 amplifier (R&S SR8130
only)
The "present" switch position is required for the R&S SR8250A system.