Chapter 4 Putting into Operation
5300.9677.72 - 4.9 - EN-4
2.2.5 Configuring Rear Panel Ethernet Connection
) Select Transmitter > Setup > Ethernet.
The Ethernet window opens.
Fig. 1 Ethernet window (with basic settings displayed)
You can enter the following settings in the Ethernet window:
Tx Mode Used to set a standby system (if available):
a)
Standalone (single transmitter)
1+1 (1+1 standby system)
n+1 (n+1 standby system)
Tx Reserve A1 to A8, B (used to select the transmitter number in a 1+1 or n+1
standby system)
Parallel IO Used to activate/deactivate the parallel remote-control interface of the
transmitter
ParIO Inhibit Status For local mode, the messages from the parallel remote-control interface
of the transmitter are activated/deactivated
Additional Amplifier Operation with/without separate R&S VU813 amplifier (R&S SR8130
only)
The "present" switch position is required for the R&S SR8250A system.
a) With 1+1 and n+1 systems, the IP address of the rear Ethernet interface is set to a fixed value.
Selection Description
Front Ethernet
IP Address IP address
Subnet mask Subnet mask
Selection Description