5300.9677.71 - 5.61 - EN-4
A further application is the virtually synchronous transmission of identical signals. This re-
quires both Static Delay and Pilot Phase to be appropriately set. If the wrong values are
used, the stereo channel crosstalk can deteriorate at the reception site, for example.
2.8 Output Stage Menu
You can use the Output Stage menu to enter settings in the RF power output stage and
review their status.
2.8.1 Output Stage > Status Menu Window
You can use the Status menu window to monitor the status of the output stage. In the case
of transmitters with an additional external amplifier (system R&S SR8250A) the menu win-
dow provides separate displays for the internal amplifier and the separate amplifier, as well
as for the absorber.
Without separate amplifier
Display Description
Op Mode Status of the transmission operation
Forward Power Output power status
Power Regulation
VSWR Status of the VSWR (reduced output power when SWR too high)
Temperature Ok: Transmitter temperature is OK.
Amplifier Status
RF In Status of the RF input signal
Temperature Ok: Transmitter temperature is OK.