Chapter 6 Maintenance
5300.9677.72 - 6.7 - EN-4
9. At the end of the procedure, go to Report to call the report on the completed update.
10.Use Close to close the report window and use Cancel to close the R&S Software Dis-
tributor.
The transmitter carries out a reboot.
1.2.1 On Rebooting
Note On the initial rebooot, do not switch off the transmitter in any circumstances until the system
overview is displayed.
Once the system has been powered up the boot loader is updated. This takes about 30 sec-
onds. During this procedure the transmitter does not respond to any commands, either from
the keyboard or the browser.
The transmitter then updates the individual software and hardware components. This pro-
cedure is completed in around 4 minutes, and the system overview is then displayed.
It takes about a further 15 minutes for the web interface cache memory to be refreshed. You
are then able to log onto the system again via the web browser.
1.2.2 Checking New Software Version
) Open the Transmitter > Device Info > Device menu window.
The current software version number is displayed under the entry SW/FW Version.