62 / 327 - EN -
Visualisation of the example:
Firing program sequence:
The temperature rises at the entered, ascending ramp (heating up) [ramp rate] until the kiln reaches the soak or
target temperature.
It then soaks (dwells) at the soak temperature for the soak period.
It then runs the next segment until the end of the program is reached.
It is possible to control ascending ramps (heating up) & descending ramps (cooling down).
Ascending ramps (heating up) and descending ramps (cooling down) are referred to as the "ramp rate".
The ramp rate is set in values between 1 and 999°C/h or as “FULL” (full load heating) or “END” (end of the
program).
The soak/target temperature is settable over the range 0 to 1320°C (2408°F).
The soak period is settable over the range 00:00 (no soak) to 99 hours 59 mins.
Note:
During soaking, the kiln temperature and the remaining soak time appear on the display at intervals of 15 seconds.
User information:
For simple firing such as biscuit firing, two segments are sufficient, more complex firings such as crystal glazes or glass
production require several segments.