6.5.4. Programming the “FULL” ramp rate
An unregulated full load heating/cooling ramp (“FULL”) can be programmed.
Display Meaning Description Remark
Pr. 1
Program
number
Select the firing program that is to be
changed.
See Section 6.5.1.
Indicator in
the segment
display
Select the segment with the heating
ramp to be changed into a cooling
ramp.
See Section 6.5.1.
150°C/HR
Heating ramp
Cooling ramp
The ramp rate for the heating or
cooling ramp is shown in the main
display.
Possible main display:
„0,1
°C/h-9,9
°C/h“,
„10
°C/h-999
°C/h“
FULL
Heating ramp
Cooling ramp
Press or hold down the d key until
“FULL” appears in the main display.
• “FULL” heats or cools as fast as
possible.
• The “FULL” value is one step
above the ramp rate “999°C/h”.
*The keys h or g can also be held down for faster input.