EasyManua.ls Logo

Rohde ST 411 - Error Messages; Error Message Display; Reading Error Messages; General Error Messages

Rohde ST 411
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
76 / 327 - EN -
9.2. Reading error messages
Step Activity Remark
1
Press the h key to obtain more information on
the error.
The first press will display the maximum temperature
reached in the firing.
2
Press the h key again to display the length of
time the error has been present.
The buzzer will mute.
9.3. General error messages
Display Description Cause of error / Troubleshooting
ERROR: 0
Internal data error
Technical service required:
The controller cannot be repaired on site
and must be sent to the manufacturer for
repair.
ERROR: 1
Heating error.
The kiln temperature is not increasing as
required.
The kiln has been on full power for 15 minutes,
but the temperature has not increased by at
least 2°C.
Kiln door or lid not completely closed.
Defective door switch
Door switch needs to be adjusted.
Heating element circuit open
Heating elements too old
Electrical power phase failure
Contactor failure
ERROR: 2
Thermocouple or wiring for thermocouple
disconnected.
Get thermocouple and wiring
checked.
Replace thermocouple if necessary.
ERROR: 3
Thermocouple with reversed polarity.
Kiln temperature apparently below
-40°C
This is an installation fault.
Get wiring checked.
ERROR: 4
Cooling error
The kiln has been on zero power for 30
minutes, but the kiln temperature has not fallen
by at leastC.
Contactor failure
(contacts possibly welded)
Thermocouple disconnected or
resistance too high.
ERROR: 5
Set kiln temperature exceeded.
Desired temperature
Overshoot allowed
Below 100 °C + 60 °C
More than 100 °C
but less than 200 °C
+ 50 °C
More than 200 °C
but less than 600 °C
+ 30 °C
More than 600 °C + 20 °C
The kiln temperature has exceeded the
desired temperature by a preset limit.
The contactor is not working
(contactor hanging).
Replace contactor
ERROR: 6
The maximum duration of the firing process
exceeded.
The duration of the firing process
exceeds a limit value set in the factory.
Deactivated at the factory.
If you want to set a maximum firing
time, please contact ROHDE Service.

Table of Contents