Reference Manual
00809-0100-4360, Rev BA
August 2008
3-5
Rosemount 1151
HART COMMUNICATOR
Figure 3-4. HART Communicator Menu Tree
1 DEVICE
SETUP
2PV
3AO
4LRV
5URV
1 PROCESS
VARIABLE
2 DIAGNOSTICS
AND SERVICE
3 BASIC SETUP
4DETAILED
SETUP
5 REVIEW
Online Menu
1Pres
2 % Rnge
3AO
1 TEST DEVICE
2 Loop Test
3 CALIBRATION
1Self Test
2Status
1RERANGE
2 ANALOG
OUTPUT TRIM
3 SENSOR TRIM
1SENSORS
2 SIGNAL
CONDITION
3OUTPUT
CONDITION
4 DEVICE
INFORMATION
4RECALL
FACTORY TRIM
1 Keypad Input
2 APPLY VALUES
1 D/A trim
2 Scaled D/A trim
1 Zero Trim
2 Lower Sensor Trim
3 Upper Sensor Trim
4 Sensor Trim Points
1 Keypad Input
2 Apply Values
1Date
2 Descriptor
3 Message
4 Write Protect
5 Meter Type
1Tag
2 Unit
3 RANGE VALUES
4 DEVICE
INFORMATION
5 Xfer Fnctn
6 Damp
1 PRESSURE
SENSOR
2 TEMP SENSOR
1 Sensor Temp
2 Temperature Unit
1 PROCESS VARIABLE
2 SENSOR SERVICE
3 Unit
1Press
2% Rnge
3AO
1SENSOR
TRIM
2 Characterize
1 Zero Trim
2 Lower Sensor
Trim
3 Upper Sensor
Trim
4 Sensor Trim
Points
1 PROCESS
VARIABLES
2 RANGE
VALUES
3Unit
4 Xfer Fnctn
5Damp
6 ALM/SAT
LEVELS
1 FIELD DEVICE
INFO
2 SENSOR INFO
3Self Test
4 DIAPHRAGM
SEAL INFO
1Press
2 % Rnge
3AO
1 Keypad Input
2 Apply Values
1 Hi Alarm
2Lo Alarm
3 Hi Sat
4Lo Sat
5 AO Alrm Type
1Press
2 % Rnge
3AO
1 Loop Test
2 D/A Trim
3 Scaled D/A Trim
4 AO Alrm Type
1Poll Addr
2 Num Req Preams
3 Burst Mode
4 Burst Option
1 Meter Type
2 CUSTOM METER
SETUP
3 Custom Meter Value
1Meas Type
2 Isoltr Matl
3 Fill Fluid
4 Flange Type
5 Flange Matl
6 O Ring Matl
7 Drain Vent Matl
1 Sel. Dec. Pt. Pos.
2 CM Upper Value
3 CM Lower Value
4 CM Units
5 CM xfer function
1Tag
2Date
3Descriptor
4Message
5 Model
6 Write Protect
7 Local Keys
8 Revision #s
9 Final Asmbly Num
10 Dev ID
11 Distributor
1 Num Remote Seal
2RS Type
3 Seal Fill Fluid
4 RS Isoltr Matl
1 Sensor Trim
2 Analog Output Trim
1 PROCESS
VARIABLES
2 ANALOG
OUTPUT
3 HART OUTPUT
4 METER
OPTIONS
14 mA
220 mA
3 Exit
1 Manufacturer
2 Model
3 Meas Type
4 Module Rnge
5 Unit
6 LSL
7 USL
8 LRV
9 URV