Reference Manual
00809-0100-4809, Rev DA
Appendix A: Specifications and Reference Data
September 2015
93
Specifications and Reference Data
Transmitter housing style
Material
Conduit entry
size
D 1-7
2M
Junction Box housing with output for remote
display and interface
SST
1
/2-14 NPT • — ★
5A
(11)
Wireless PlantWeb housing Aluminum
1
/2-14 NPT • — ★
5J
(11)
Wireless PlantWeb housing SST
1
/2-14 NPT • — ★
7J
(9)(12)
Quick Connect (A size Mini, 4-pin male
termination)
N/A N/A • — ★
1C PlantWeb housing Aluminum G
1
/2 • •
1L PlantWeb housing SST G
1
/2 • •
2C Junction Box housing Aluminum G
1
/2 • —
2G
Junction Box housing with output for remote
display and interface
Aluminum G
1
/2 • —
Performance class
(13)
3051S MultiVariable SuperModule, measurement types 1, 2, 5, and 6
3
(14)
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability. limited
12-year warranty
• • ★
5 Classic MV: 0.85% flow rate accuracy, 8:1 flow turndown, 5-yr. stability — • ★
3051S Single Variable SuperModule, measurement types 3, 4, 7, and D
1
Ultra: up to 0.9% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited
12-year warranty
• — ★
2 Classic: up to 1.1% flow rate accuracy, 8:1 flow turndown, 5-year stability • — ★
3
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability,. limited
12-year warranty
• • ★
Wireless options
(10)
(requires option code X and wireless PlantWeb housing)
Update rate, operating frequency and protocol D 1-7
WA User configurable update rate • — ★
Operating frequency and protocol
3 2.4 GHz DSSS, IEC 62591 (WirelessHART
®
) • — ★
Omni-directional wireless antenna
WK External antenna • — ★
WM Extended range, external antenna • —
Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.