Appendix A: Specifications and Reference Data
September 2015
125
Specifications and Reference Data
Configuration buttons
D4
(16)
Analog zero and span
DZ
(23)
Digital zero trim
Ground screw
(19)(24)
V5 External ground screw assembly ★
Typical model number: 3051CFA D L 060 D C H P S 2 T1 0 0 0 3 2 A A 1
1. Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
2. See the DP Flow Product Data Sheet (document number 00813-0100-4485) for Pipe I.D. table.
3. Available in remote mount applications only.
4. The cage nipple is constructed of 304 SST.
5. Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured
to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
6. For local addressing and configuration, M4 (Local Operator Interface) is required.
7. Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option
code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic Safety (option code I7).
8. Only available with C6, E2, E5, I5, K5, KB and E8 approval. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, CT.
9. Only available with Wireless Output (output code X).
10. Not available with Product certifications options E8, K8, E5, K5, C6, K6, E7, K7, E2, K2, E3, KB, KD.
11. Applies to assembled flowmeter only, mounting not tested.
12. Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.
13. Not available with Transmitter Connection Platform 6.
14. Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
15. Only valid with F
OUNDATION Fieldbus output (output code F).
16. Only available with 4-20 mA HART output (output Code A).
17. Dust approval not applicable to output code X.
18. Nonincendive certification not provided with Wireless output option code (X).Not available with Wireless Output (output code X).
19. Not available with Wireless Output (output code X).
20. Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7.
21. Not available with FOUNDATION Fieldbus (Output Code F) or Wireless Output (output code X) or Low Power (output code M).
22. The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product Certification codes IA, IB, and IE.
23. Only available with 4-20 mA HART Output (output code A) and Wireless output (Output Code X).
24. The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
Table 6. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.