EasyManua.ls Logo

Rosemount 8712 - Sensor to Remote Mount Transmitter Connections

Rosemount 8712
212 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4664, Rev BA
January 2010
2-15
Rosemount 8712
Sensor to Remote Mount
Transmitter Connections
Connect coil drive and electrode cables as shown in Figure 2-13.
Do not connect AC power to the sensor or to terminals 1 and 2 of the
transmitter, or replacement of the electronics board will be necessary.
Figure 2-13. Wiring Diagram
Rosemount 8712 Transmitter Rosemount 8705/8707/8711/8721 sensors
11
2 2
17 17
18 18
19 19

Table of Contents