Table A-19. Flanged-Style Flowmeter (
1
/2-through 2-in./15 through 50 mm Line Sizes)
Nominal Size
Inch (mm)
Flange
Rating
Face-to-face A
Inch (mm)
A-ANSI RTJ
Inch (mm)
Diameter B
Inch (mm)
C
Inch (mm)
D
Inch (mm)
Weight
lb (kg)
½ (15) Class 150
Class 300
Class 600
Class 900
6.9 (175)
7.2 (183)
7.7 (196)
8.4 (213)
7.7 (196)
7.7 (196)
8.4 (213)
0.54 (13,7)
0.54 (13,7)
0.54 (13,7)
0.54 (13,7)
7.6 (193)
7.6 (193)
7.6 (193)
7.6 (193)
9.1 (4,1)
10.4 (4,7)
10.8 (4,9)
15.3 (6,9)
PN 16/40
PN 100
6.1 (155)
6.6 (168)
0.54 (13,7)
0.54 (13,7)
7.6 (193)
7.6 (193)
10.4 (4,7)
12.3 (5,6)
JIS 10K/20K
JIS 40K
6.3 (160)
7.3 (185)
0.54 (13,7)
0.54 (13,7)
7.6 (193)
7.6 (193)
10.1 (4,5)
13.5 (6,1)
1 (25) Class 150
Class 300
Class 600
Class 900
Class 1500
7.5 (191)
8.0 (203)
8.5 (216)
9.4 (239)
9.4 (239)
8.0 (203)
8.5 (216)
8.5 (216)
9.4 (239)
9.4 (239)
0.95 (24,1)
0.95 (24,1)
0.95 (24,1)
0.95 (24,1)
0.95 (24,1)
7.7 (196)
7.7 (196)
7.7 (196)
7.7 (196)
7.7 (196)
12.3 (5,6)
15.0 (6,8)
15.8 (7,2)
24.3 (11,0)
24.3 (11,0)
PN 16/40
PN 100
PN 160
6.3 (160)
7.7 (195)
7.7 (195)
0.95 (24,1)
0.95 (24,1)
0.95 (24,1)
7.7 (196)
7.7 (196)
7.7 (196)
13.5 (6,1)
19.5 (8,8)
19.5 (8,8)
JIS 10K/20K
JIS 40K
6.5 (165)
7.9 (200)
0.95 (24,1)
0.95 (24,1)
7.7 (196)
7.7 (196)
13.7 (6,2)
17.4 (7,9)
1 ½ (40) Class 150
Class 300
Class 600
Class 900
Class 1500
8.2 (208)
8.7 (221)
9.4 (239)
10.4 (264)
10.4 (264)
8.7 (221)
9.2 (234)
9.4 (239)
10.4 (264)
10.4 (264)
1.49 (37,8)
1.49 (37,8)
1.49 (37,8)
1.49 (37,8)
1.49 (37,8)
8.1 (206)
8.1 (206)
8.1 (206)
8.1 (206)
8.1 (206)
17.6 (8,0)
23.0 (10,4)
25.3 (11,5)
36.3 (16,5)
36.6 (16,6)
PN 16/40
PN 100
PN 160
6.9 (175)
8.2 (208)
8.4 (213)
1.49 (37,8)
1.49 (37,8)
1.49 (37,8)
8.1 (206)
8.1 (206)
8.1 (206)
19.3 (8,8)
27.9 (12,7)
29.3 (13,3)
JIS 10K/20K
JIS 40K
7.3 (185)
8.5 (215)
1.49 (37,8)
1.49 (37,8)
8.1 (206)
8.1 (206)
18.6 (8,4)
25.6 (11,6)
2 (50) Class 150
Class 300
Class 600
Class 900
Class 1500
9.3 (236)
9.8 (249)
10.5 (267)
12.8 (325)
12.8 (325)
9.8 (249)
10.4 (264)
10.7 (271)
12.9 (328)
12.9 (328)
1.92 (48,8)
1.92 (48,8)
1.92 (48,8)
1.92 (48,8)
1.79 (45,5)
8.5 (216)
8.5 (216)
8.5 (216)
8.5 (216)
8.5 (216)
4.7 (119)
4.7 (119)
4.7 (119)
4.7 (119)
22.0 (10,0)
26.0 (11,8)
29.6 (13,4)
59.4 (26,9)
59.4 (26,9)
PN 16/40
PN 64
PN 100
PN 160
8.0 (203)
9.2 (234)
9.6 (244)
10.2 (259)
1.92 (48,8)
1.92 (48,8)
1.92 (48,8)
1.92 (48,8)
8.5 (216)
8.5 (216)
8.5 (216)
8.5 (216)
4.7 (119)
4.7 (119)
4.7 (119)
23.0 (10,4)
30.6 (13,9)
36.4 (16,5)
38.7 (17,6)
JIS 10K
JIS 20K
JIS 40K
7.7 (195)
8.3 (210)
9.8 (249)
1.92 (48,8)
1.92 (48,8)
1.92 (48,8)
8.5 (216)
8.5 (216)
8.5 (216)
4.7 (119)
4.7 (119)
4.7 (119)
19.5 (8,8)
20.1 (9,1)
28.3 (12,8)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 8800D Series and is the answer not in the manual?

Rosemount 8800D Series Specifications

General IconGeneral
TypeVortex Flow Meter
Measurement PrincipleVortex Shedding
Operating Temperature-40 to 185°F (-40 to 85°C)
Storage Temperature-40 to 185°F (-40 to 85°C)
Communication ProtocolsFOUNDATION Fieldbus
Material316 stainless steel
Fluid TypeLiquid, Gas, Steam
Line Size1/2 to 8 inches (15 to 200 mm)
ApprovalsATEX, IECEx, CSA, FM
Output Signal4-20 mA
Process ConnectionFlanged, Wafer, Threaded
Electrical ConnectionM20
Protection RatingIP66
Mounting StyleWafer, Flanged