EasyManuals Logo

Rosemount 8800D Series User Manual

Rosemount 8800D Series
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Reference Manual
00809-0100-4004, Rev BA
August 2010
B-5
Rosemount 8800D
Chinese Certifications (NEPSI)
Flameproof Certification
E3 Certification No. GYJ071327X
Ex d [ia] IIC T6 (-50°C to 70°C)
Intrinsic Safety
I3 Certification No. GYJ071171X
Ex ia IIC T4/T5
T4: (-60°C to 70°C)
T5: (-60°C to 40°C)
Input Parameters:
U
i
= 30 Vdc
I
i
= 185 mA
P
i
= 1.0 W
C
i
= 0 F
L
i
= 0.97 mH
Type N Certification
N3 Certification No. GYJ071193X
Ex nAnL IIC T5 (-40°C to70°C)
42 Vdc Max
K3 E3, I3, and N3 Combination
Japanese Certifications (TIIS)
Flameproof Certification
E4 Transmitter - Ex d [ia] T6
Remote Sensor - Ex ia IIC T6
Certificate Description
TC17816 8800D with display, without MTA option
TC17817
8800D without display, without MTA option
TC17905 8800D with display, with MTA option
TC17906 8800D without display, with MTA option

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 8800D Series and is the answer not in the manual?

Rosemount 8800D Series Specifications

General IconGeneral
TypeVortex Flow Meter
Measurement PrincipleVortex Shedding
Operating Temperature-40 to 185°F (-40 to 85°C)
Storage Temperature-40 to 185°F (-40 to 85°C)
Communication ProtocolsFOUNDATION Fieldbus
Material316 stainless steel
Fluid TypeLiquid, Gas, Steam
Line Size1/2 to 8 inches (15 to 200 mm)
ApprovalsATEX, IECEx, CSA, FM
Output Signal4-20 mA
Process ConnectionFlanged, Wafer, Threaded
Electrical ConnectionM20
Protection RatingIP66
Mounting StyleWafer, Flanged