Reference Manual
00809-0100-4004, Rev BA
August 2010
5-19
Rosemount 8800D
NOTE
Do not pull the adapter more than 1.5-in. (40 mm) from the top of the support
tube. Damage to the sensor may occur if the sensor cable is stressed.
Detach the Meter Adapter
The above instructions will provide access to the meter body. Use the
following steps if it is necessary to remove the coaxial cable:
1. Loosen and remove the two screws that hold the union onto the
meter adapter and pull the union away from the adapter.
2. Loosen and remove the sensor cable nut from the other end
of the union.
3. Loosen and disconnect the conduit adapter or cable gland from the
meter adapter.
Figure 5-13. Coaxial Cable Connections
½ NPT Conduit
Adapter or Cable
Gland (Supplied by
Customer)
Coaxial Cable
Meter Adapter
Union
Washer
Sensor Cable Nut
Support Tube
Meter Body
Nut

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosemount 8800D Series and is the answer not in the manual?

Rosemount 8800D Series Specifications

General IconGeneral
TypeVortex Flow Meter
Measurement PrincipleVortex Shedding
Operating Temperature-40 to 185°F (-40 to 85°C)
Storage Temperature-40 to 185°F (-40 to 85°C)
Communication ProtocolsFOUNDATION Fieldbus
Material316 stainless steel
Fluid TypeLiquid, Gas, Steam
Line Size1/2 to 8 inches (15 to 200 mm)
ApprovalsATEX, IECEx, CSA, FM
Output Signal4-20 mA
Process ConnectionFlanged, Wafer, Threaded
Electrical ConnectionM20
Protection RatingIP66
Mounting StyleWafer, Flanged

Related product manuals