Instruction To refill the coolant the following steps are necessary.
Step
Procedure
1
Open the radiator cap (1) on the expansion tank (2).
2 Check the coolant level. The coolant level must be filled up to the top (see
Sketch).
3
Inspect coolant with densimeter or glycol tester. Strongly discolored or
thickened coolant must be replaced.
ATTENTION
Use only coolant as recommended in the current Operators Manual and SI-912 i-
001 “Selection of suitable operation fluids“, current issue.
Step
Procedure
4
If necessary, replenish with coolant of same composition.
5 Tighten the radiator cap by hand.
NOTE
The radiator cap must be tightened until the stop lug is contacted.
Figure 6.3: Coolant check/replenish TYPICAL
1
Radiator cap
2
Expansion tank
Effectivity: 912 i Series
Edition 2/Rev. 0
12–10–00
Page 5
September 01/2018

Table of Contents

Other manuals for Rotax 912 i series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 i series and is the answer not in the manual?

Rotax 912 i series Specifications

General IconGeneral
Number of Cylinders4
Max Power100 hp (73.5 kW)
Max Power Output RPM5800 rpm
Ignition SystemDual electronic ignition
Oil SystemDry sump, forced lubrication with separate oil tank
Reduction Gear Ratio2.43:1
TBO2000 hours
Engine Type4-stroke, horizontally opposed
Displacement1352 cm³
Bore x Stroke84 mm x 61 mm
Max Torque128 Nm
Fuel TypeAvgas 100LL or unleaded automotive gasoline
Fuel SystemElectronic fuel injection
Cooling SystemLiquid/air-cooled

Related product manuals