EbV Product documentation THETA NORM/UNIT
5-13
5.1.2.7.2 Operating states
After entering of the information level by means of the information key ¤, a query of all available operating
statuses such as counter numbers, capacities etc. can be made by turning the rotary pushbutton anti-
clockwise.
Ambient temper.
Mixing circuit 2
Nominal/actual value Remote control necessary (..33..)
Thermostat function
Unmixed heating circuit
THERMOSTAT
HC
Room thermostat function
activated
OFF = no room temperature limit
(..2..)
Thermostat function
Mixing circuit 1
THERMOSTAT
MC-1
Room thermostat function
activated
OFF = no room temperature limit
(..3..)
Thermostat function
Mixing circuit 2
THERMOSTAT
MC-2
Room thermostat function
activated
OFF = no room temperature limit
(..33..)
Boiler temp. solid fuel Actual value Solid fuel charging pump at
variable output
(..VV..)
Buffer temp. Solid fuel
boiler
Actual value Solid fuel charging pump at
variable output, corresponds to
SBUS or BUSF, according to
configuration.
(..VV..)
Upper buffer sensor Nominal/actual value Buffer charging pump at var. output (..VV..)
Lower buffer sensor Nominal/actual value Buffer sensor 2 at var. input (..VV..)
Solar panel sensor Actual value Solar pump at var. output (..VV..)
(..VV..)
Solar tank Actual value Solar pump at var. output (..VV..)
Solar panel return flow
sensor
Actual value Solar pump at var. output
Return flow sensor at var. input
(..VV..)
Solar tank
changeover
Actual value Solar valve activated (..VV..)
Information Display
(Example)
Function Application
Status
Unmixed circuit
AUTO-P1 ECO
HC ON
Operating mode/é-program/mode
status of heating pump
(..2..)
Status
Mixing circuit 1
AUTO-P1 ECO
MC-1 ON
Operating mode/é-program/mode
status of heating pump
(..3..)
Status actuator
Mix.valve-1
MIX.VALVE-1
OPEN
Display of direction
OPEN-STOP-CLOS
(..3..)
Status
Mixing circuit 2
AUTO-P1 ECO
MC-2 ON
Operating mode/é-program/mode
status of heating pump
(..33..)
Status actuator
Mix.valve-2
MIX.VALVE-2
STOP
Display of direction
OPEN-STOP-CLOS
(..33..)
INFORMATION Displayed value Remarks Application

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotex Controller Series and is the answer not in the manual?

Rotex Controller Series Specifications

General IconGeneral
BrandRotex
ModelController Series
CategoryController
LanguageEnglish

Related product manuals