Section 4 Control Denitions H85A Manual
www.rottlermfg.com
4-9
Operation Screen: Operation Tab
This is the screen where the honing operation will be run from. At the top under the Operation Tab are 2
readouts. The rst is Z Distance From Zero. This reading shows the location of the spindle from the zero
point. The second is Stone Diameter To Go. This readout shows how much the stones must still feed out
to reach the Total Stock Removal setting.
Load Reading Button
This is a non-functional button. This is where the spindle motor load reading is displayed. The button color
will change as load increases. Green indicates that the motor load is in its optimal area. Yellow indicates
that the motor load is slightly high. Red indicates that the motor load is excessive.
Zero Stone Diameter Button
This button is used to set the zero setting for the stone diameter.
Total Stock Removal Value Box
This is where the operator will enter a value for the amount of stock to be removed from a cylinder.