Section 5 Operating Instructions H85A Manual
www.rottlermfg.com
5-19
Loading the Block
The next step is to load the block that will be honed onto the xture. In this tutorial the optional auto rotate
xture is shown. The block loading procedure is the same for the manual xture.
Select the block that will be used. In this tutorial a small block V-8 will be used.
Set the riser blocks on the xture cradle so that the pan rails are sitting on the surface that was
determined to be closest to ideal.
The main caps must be on when a V-Block is honed and on an Inline Block if
the optional clamp arms are not be used.
Place the clamp bar tube through the main
bore of the block. Be certain that the machined
ats at the end of the clamp bar tube are in a
vertical position.