Section 4 Control Denitions H85A Manual
www.rottlermfg.com
4-11
COOLANT PUMP and LAMP BUTTONS
These buttons turn the coolant pump and lamps on or off. When they are
on they will be red in color. The coolant pump and lamps have an
independent power supply and will work even if the E-STOP is engaged.
PLATEAU Button
This button will turn the Plateau mode on or off. When it is on the
button will turn red and the numbers of strokes to be used for the
process is displayed on the button.
Pop Up Windows and Menus
Number Pad
This window will pop up when the operator touches a value box.
The operator will input the value desired and then touch ENTER to
place the value in the value box.