INSTALLATION REPORT
REV 062718
H85 SERIES
OFFICE USE ONLY
Route to: Servicer Mgr Accounting Andy Accounting Warranty Exp Date ________
ROTTLER MANUFACTURING MUST HAVE THIS REPORT RETURNED
TO PROPERLY QUALIFY WARRANTY ON EQUIPMENT
Customer:____________________________ Address:_______________________________________
City:_________________________________ State:_____ Zip:_________ Phone:_______________
Country:______________________________
Machine Model:___________ Serial Number:__________ Representative:________________________
MACHINE INSTALLATION: Electrical information MUST be complete to validate this report.
Customer responsibility prior to the arrival of Rottler Sales/Service technician.
Please Initial each item when it is completed.
VERY IMPORTANT: Modern design machines contain electronic low voltage
circuitry that provides great advantages and a better machine life. BUT, you
must have an excellent, stable, isolated power supply along with an isolated
ground. If not, electrical noise problems are likely to interfere with machine
operation unexpectedly.
Customer is responsible for providing electricity to machine in a manner that meets the local
electrical code requirements.
______Remove machine from truck. Weight: 2,500 lbs.
______Provide solid foundation for machine.
______Remove xturing and misc. from machine and clean.
______Install machine on foundation with jack pads under jacking bolts.
______Level machine. When level all leveling bolts should have equal pressure on them.
______This machine requires between 208 and 240 Volts AC, Three Phase, 50/60 Hz, isolated power
supply.
If this machine is being installed in a location without 3 phase power, follow
the single phase wiring hookup shown in the installation section of the
manual
______Measure the incoming voltage between L1 and L2, L2 and L3, L1 and L3. Measure the incoming
AC voltage at least twice during installation.
L1 to L2 __________ VAC L2 to L3 ___________VAC L1 to L3 __________VAC
L1 to L2 __________ VAC L2 to L3 ___________VAC L1 to L3 __________VAC
______This machine should have an external breaker rated at 25 Amps, continuous draw.
______Measure each leg of the incoming supply to ground. Sometimes you may nd a “high” leg to
ground. When this happens make sure the high leg is running to L3.
L1 to ground ___________VAC L2 to ground __________VAC L3 to ground ________VAC
Neutral and machine ground are not the same thing. You should measure an
open circuit between Neutral and ground.