SYSTEM PARAMETERS—SWITCHING CLOCK PROGRAMS
40
P:C13 0–9 Day of week. Parameter shows which day the clock program will
be working.
0: Monday to Sunday
1: Sunday
2: Monday
3: Tuesday
4: Wednesday
5: Thursday
6: Friday
7: Saturday
8: Monday to Friday
9: Saturday to Sunday
P:C14 0–23 Hour. Parameter shows which hour the clock program will be
working.
P:C15 0–59 Minutes. Parameter shows which minute the clock program will
be working.
P:C16 0–59 Seconds. Parameter shows which second the clock program will
be working.
P:C17 0–9 Priority of switching program. Parameter defines the priority of
the switching program. 0 lowest priority, 9 highest priority.
P:C18 0101–1231 Date of Start. Parameter shows which day and month the clock
program will be working.
P:C19 0101–1231 End Date. Parameter shows which day and month the clock pro-
gram will end.
P:C1E 0–1 Reset all switching programs. All switching programs will be
deleted and all switching programs will stop.
Parameter Range Service Level 2 Parameter