SPECIFICATIONS—OUTPUTS
56
OUTPUTS
FEIG Interface Bus II
Max. Distance:
TTL communication interface to interface converter board TST RFUxCom
for communication with external mounted I/O expansion board TST
RFUxK
100 ft. (30 m)
FEIG Interface Bus III
Max. Distance:
TTL communication interface to interface converter board TST RFUxCom
for communication with a second prepared door controller TST FURR
100 ft. (30 m)
Supply Output I
Max. Load:
Nominal value: 24 VDC ± 5%
3.5 A (Includes brake, all plug-in modules, expansion boards, and supply
output II, etc.)
Overload protected by self-resetting semiconductor fuse
Short circuit protected by central switching regulator (switch off the com-
plete control system supply)
Supply Output II (Part of Supply Output
I)
For electronic limit switches and safety edge evaluation
Nominal value 11.3 V/max. 250 mA
Overload protected, short circuit proof, and self resetting
Motor/Drive Output
Overload:
Max. Length of Motor Cable:
3 hp motor (derating for single phase supply)
5 Amps @ 480 V service voltage
10 Amps @ 230 V service voltage
20 A for 0.5 seconds (motor overload protection is provided)
100 ft. (30 m)
Shielded cable is required; motor lines have to be separated from any
other wires. A separate motor contactor is NOT provided. ATTENTION:
High voltage on output terminals is also possible in E-STOP mode.
Brake Output 24 VDC/2.5A (supplied by internal power)
Electrical switch (e.g, transistor based)
2-pole plugable terminal
Short and overload protected
Prepared for SEW brake BMG4T, 40 Nm, 56 AC/24 DC
Additional noise suppression on electromechanical brake required (e.g, RC)
Auxiliary Relays Outputs
(115 V is more important than pluga-
ble terminals)
Change over contact elements
Potential free
250 VAC/¹/ hp
30 VDC/max. 10A/min. 10 mA
Pilot duty B300, R300
250 V permitted only when con-
necting the same phase as the sup-
ply voltage. Contacts used once for
power switching (>100 mA) can no
longer switch low currents.
Brake Resistance Load Max. 2 hp (1.5 kW) for max. 0.5 seconds
Repetition rate min. every 20 seconds
Brake resistor is mounted on the heat sink
Relay Outputs If inductive loads are switched (e.g, additional relays), there must be
equipped with recovery diodes and appropriate noise suppression means
(e.g, regenerate diodes, varistors, RC elements)
Be careful in switching capacitive loads as they are often in external power
supplies or LED lights
Test Signal Output 24 VDC/min. 10 mA/max. 100 mA
Resistance load only
Short and overload protected
Mainly prepared for test inputs on photo eyes