Loading...
For experienced Users: AT commands
64 SAGEM RT3000
Datei 8115AD002-Total.doc
Datei gespeichert 24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04, 18:17
Status Release
Command Function (factory setting in bold print)
n= 0 – 127 : command line editing character
ATS5? Displays the value of status register 5
ATV[n]
Set result code format mode. This parameter setting determines
the contents of the header and trailer transmitted with result
codes and information responses.
Parameters:
n = 0 Information response: <text><CR><LF>
Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code>
<CR><LF>
ATZ Load standard configuration
AT&C[n]
Set circuit Data Carrier Detect (DCD) function mode.
Parameters:
n = 0 : DCD line is always ON
1 : DCD line is ON in the presence of data carrier only
(Default).
AT&D[n] Set circuit Data Terminal Ready (DTR) function mode.
Parameters:
n = 0: TA ignores status on DTR.
1: ON->OFF on DTR: Change to command mode while
retaining the connected call.
2: ON->OFF on DTR: Disconnect call, change to command
mode. During state DTR = OFF is auto-answer off. (Default)
AT&F Load factory setting
AT&k[n] Local data flow control (DTE $ DCE)
&k0 Data flow control OFF
&k3 Data flow control RTS/CTS
AT&V Displays current configuration
AT&W Save configuration
A/ Repeat previous command line
AT+FCLASS=n
Setting the Faxclass
Parameters:
n = 0: normal operation
1: PC Fax enabled
AT+CGATT=n
PS attach or detach
Parameters:
n = 0 detached
1 attached