EasyManua.ls Logo

SAMES KREMLIN Cyclomix Evo - Page 100

SAMES KREMLIN Cyclomix Evo
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100
Member of Exel group
DRT582165110
A - 2023/03
Data mapping for Modbus only
Write/Read Address Description Type Size Unité
R 30002 Machine state
unsigned word
16 bits -
R 30003 Production flow
unsigned word
16 bits cc * 10/min
R 30004 Ratio A/B
unsigned word
16 bits ratio * 100
R 30005 Current recipe
unsigned word
16 bits -
R 30006 Potlife 1
unsigned
double word
32 bits sec
R 30008 Potlife 2
unsigned
double word
32 bits sec
R 30010 Faults_1
unsigned word
16 bits -
R 30012 Faults_2
unsigned word
16 bits -
R 30013 Ratio A/C
unsigned word
16 bits ratio * 100
R 30014 A consumption
unsigned
double word
32 bits cc
R 30016 B consumption
unsigned
double word
32 bits cc
R 30018 C consumption
unsigned
double word
32 bits cc
R 30020
A consumption
saved
unsigned
double word
32 bits cc
R 30022
B consumption
saved
unsigned
double word
32 bits cc
R 30024
C consumption
saved
unsigned
double word
32 bits cc
W 30039 PLC_Command_1
unsigned word
16 bits -
W 30040 PLC_Command_2
unsigned word
16 bits -
R 30041 Flag_1
unsigned word
16 bits -
R 30042 Flag_2
unsigned word
16 bits -

Table of Contents