147
Member of Exel group
DRT582165110
A - 2023/03
Potlife Switching to rege-
neration or flushing
mode depending on
the ''successive
regeneration
before flush"
parameter and of
the ''POTLIFE
ACHIEVED' infor-
mation banner
NO Potlife monitoring
time has reached
the time defined in
the "potlife"
parameter
The ''Potlife'' time
counter has
reached the value
defined in the
"potlife" parame-
ter
The machine
automatically
starts a regene-
ration or a
flushing. Make
sure that the
guns are in the
flushboxes if they
are present and if
not, open the
gun(s).
Injection valve lea-
kage
Closing of all valves
(CTM, Injection,
Gun)
Display of the
default on the
screen
YES Switch to regeneration
mode and then production
The PLC receives
pulses from the B
flowmeter without
the injection valve
being controlled in
opening (including a
time for pressuriza-
tion).
Leakage on the A
circuit or on the
mixed circuit part
Check the circuit
(injection block; fit-
tings; valve...).
Repair and/or
replace the neces-
sary parts.
Check the condi-
tion of the valve
needle.
Check the condi-
tion of the seat.
Check the correct
operating of the
valve (card output
at 0,
presence of air in
the electrical out-
let,…)
A circuit leakage Display of an alarm
message
NO The machine is in
IDLE mode, so no
valve is piloted, yet
the machine sees
pulses on the A
flowmeter.
Leakage on the A
circuit or on the
mixed circuit part
Check the entire
circuit.
B circuit leakage Display of an alarm
message
NO The machine is in
IDLE mode, so no
valve is piloted, yet
the machine sees
pulses on the B
flowmeter.
Leakage on the
catalyst circuit
Check the entire
circuit.
Default
wording
Automatic
action
Expected
validation
Action following
to validation
Trigger Causes Remedies