146
Member of Exel group
DRT582165110
A - 2023/03
B solvent flow /
Trigger error
Closing of all valves
(CTM, Injection,
Gun)
Display of the
default on the
screen
Validation
by the user
Repeat the flushing cycle The current
flushing cycle cor-
reponds to B
solvent but the PLC
does not receive
pulses from the B
flowmeter
The circuit is
blocked. The
injector is
blocked. The
electrovalve is
defective. The
flowmeter is
blocked. The
flowmeter does
not send a signal.
The solvent pres-
sure is too low.
The fluid regula-
tor is not piloted
or is defective.
Check the com-
plete circuit from
the supply to the
applicator.
Check that the
inejctor is not clo-
gged with dried
catalyst. Clean or
replace if neces-
sary.
Check that the
electrovale is
properly piloted.
Output of the
card activated.
24V present.
Check the correct
operating of the
flowmeter, espe-
cially that the
gears are turning
freely.Check that
the sensor and
the sensor
connector are
correctly
screwed in.
Check the supply
pressure.
Check that the
regulator pilot
output is piloted.
Check the correct
operating of the
pneumatic cells.
Check that the
regulator is
piloted with air.
Check the correct
operating of the
regulator.
B solvent flow /
Triiger error
Display of an alarm
message with a
banner
NO Potlife monitoring
time has reached
the time defined in
the "Warning pot-
life" parameter
No circulation of
the product in the
circuits for the
time defined in
the Warning Pot-
life parameter
Open the gun (s)
to renew the pro-
duct in the circuit
(s) (in production
mode).
Warning Potlife Switching to rege-
neration or flushing
mode depending on
the ''successive
regeneration
before flush"
parameter and of
the ''POTLIFE
ACHIEVED' infor-
mation banner
NO Potlife monitoring
time has reached
the time defined in
the "potlife"
parameter
The ''Potlife'' time
counter has
reached the value
defined in the
"potlife" parame-
ter
The machine
automatically
starts a regene-
ration or a
flushing. Make
sure that the
guns are in the
flushboxes if they
are present and if
not, open the
gun(s).
Default
wording
Automatic
action
Expected
validation
Action following
to validation
Trigger Causes Remedies