57
Member of Exel group
DRT582165110
A - 2023/03
Information
provided
Explanations Example(s) of screen(s)
Pressure
Management
• Define the management of the product
pressure inside the Cyclomix® Evo.
Pressure regulator
• This option corresponds to the addition of
pressure regulators positioned between the
product feed color changers and the flow
meters.
When this option is purchased by the purchased
by the customer, a pressure regulator is
positioned on each of the base, catalyst and
diluent products.
Control without proportional valve
• The pressure adjustment of these regula-
tors is done via a plate composed of two air
regulators with pressure gauges and "or" cells
allowing to work according to a working pressure
during the phases of calibration of flowmeters,
batch, test flowmeter, color rise and production
and a rinsing pressure during the flushing
phases.
Control via proportional valve
• In order to have different pressures accor-
ding to the recipes, it is necessary to be able to
be able to control proportional valves.
Information
provided
Explanations Example(s) of screen(s)
Number of error
ratio before default
• This parameter corresponds to the number
of ratio calculations with an out-of-tolerance
result necessary to trigger an alarm.
• The calculation of the ratio is performed at
each injection, if the number of successive
injections out of tolerance reaches the number
entered, the Cyclomix
®
Evo triggers an alarm
"Ratio error" alarm.
Information
provided
Explanations Example(s) of screen(s)
Number of
regeneration
before flushing
This parameter corresponds to the number of
times the Cyclomix
®
Evo will regenerate the
product when POTLIFE is reached before
proceeding to a flushing.