EasyManua.ls Logo

Sames PPH 607 - 7 Cleaning Procedures

Sames PPH 607
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Revised A 65 6301
7. Cleaning procedures
At the end of each shift or as required by plant practices, activate the purge cycle.
Stop and shut down the system.
Clean the atomizer using dump solvent rag.
CAUTION : On no account should the atomizer or any of its component be sprayed with solvent
or high/low pressure water.
SAMES Technologies does not recommend the use of covers.
Although, if the plant chooses to protect atomizers with covers, do not use anti-static quality plastic lms
as these are conductive, and can short-circuit the high voltage.
A thin layer of dielectric grease (pure vaseline P/N # H1GMIN017) applied before covering the parts,
facilitates removal of the cover.
WARNING : Always wear safety glasses or goggles
Always wear rubber gloves when handling solvent
Work in well ventilated area when handling solvent.
WARNING : Do not soak the turbine in solvent or use a solvent spray gun. Use a rag and soft
bristle brush using an approved cleaning solution.
Procedure Components Frequency
A Tightening ring, outer ring, outer bellcup surface 8 hours
B Bellcup, inner and outer ring, outer injector surface,
outer bellcup surface, outer clip surface
120 hours
C Clip 480 hours

Table of Contents