Revised A 70 6301
7. Cleaning procedures (continued)
7.4. Nano-valve clean up
CAUTION : Do not soak the nano-valve in solvent
Step 1: Remove all o-rings
Step 2: Wipe nano-valve with a moistened rag
Step 3: Clean nano-valve with a stiff nylon brush
Step 4: Wipe again with a dry rag
Step 5: Blow out with clean compressed air
Note: for assembly see § 6.3.2 page 53
DES01634