Safety
Combics indicators comply with the
European Council Directives as well
as international regulations and
standards for electrical equipment,
electro magnetic compatibility, and
the stipulated safety requirements.
Improper use or handling can, however,
result in damage and/or injury.
t Read these operating instructions
carefully before use.
This will prevent damage to the
equipment.
! Do not use this device in hazardous
areas.
! The device may only be opened by
trained service technicians.
! Disconnect the device from power
before connecting or disconnecting
peripheral devices.
! If you operate the device under
ambient conditions subject to higher
safety standards, you must comply
with any applicable installation
regulations.
Installation
! Caution when using pre-wired
RS-232 connecting cables:
RS-232 cables purchased from other
manufacturers often have pin
assignments that are incompatible with
Sartorius products. Be sure to check
the pin assignments against the chart
in this manual before connecting the
cable, and disconnect any lines
identified differently from those
specified by Sartorius.
! Use only standard cables that have
protective grounding conductors. The
protective conductor must not be
disconnected for any reason.
! If there is visible damage to the device
or power cord: unplug the device and
secure it against further use.
! Connect only Sartorius accessories
and options, as these are optimally
designed for use with your device.
Therefore, do not use any proprietary
solutions. The operator shall be solely
responsible for installation and testing
of any modifications to Sartorius
equipment, including connection of
cables or equipment not supplied by
Sartorius. Information on operational
quality (in line with norms pertaining
to immunity) is available on request.
t If you have any problems with your
device, contact your local Sartorius
office, dealer or service center.
IP Protection Rating
CAISL models are rated to IP44 (with
option L1: IP65)
CAIS models are rated to IP69K.
The IP65/IP69K protection rating is
ensured only if the rubber gasket is
installed and all connections are
fastened securely (including the caps
on unused sockets).
Weighing platforms must be installed
and tested by a certified technician.
If you install an interface port or
battery connection after setting up
your indicator, keep the protective
cap in a safe place for future use.
The cap protects the interface
connector from vapors, moisture
and dust or dirt.
Use in Legal Metrology
When the indicator is connected to a
weighing platform and this equipment
is to be verified, ensure that the
applicable regulations regarding
verification are observed. Please read
and observe the “Guide to Verification”
on the enclosed CD.
When connecting Sartorius platforms,
observe the permitted weighing range
as listed in the “Guide to Verification
of Weighing Instruments" and the
Declaration of Conformity.
A sticker with the “Sartorius" logo was
affixed to the indicator as a control
seal following verification.
This seal will be irreparably damaged
if you attempt to remove it. This will
nullify the verification's validity. In this
case, re-verification would be required
in compliance with all relevant national
regulations and laws.
4
Warnings and Safety Instructions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius Combics 3 Series and is the answer not in the manual?

Sartorius Combics 3 Series Specifications

General IconGeneral
BrandSartorius
ModelCombics 3 Series
CategoryAccessories
LanguageEnglish

Related product manuals