PR 5211 Instrument Manual  Technical Data 
Sartorius    EN-85 
10.2  ProfiBus DP 
Standard  EN 50 179 volume 2, PROFIBUS 
DIN 19245: PROFIBUS, Process Field Bus (part 1 and 3) 
Baudrates   9.6, 19.2, 93.75, 187.5, 500 [kBps], 1.5, 3.0, 6.0, 12.0 [MBps], automatic detection 
Buffer size  8 bytes 
I/O data  8 bytes 
UserPrm  No 
Sync  YES 
Freeze  YES 
Clear  YES 
Set-Slave-Add  No 
 
10.3  Power Supply 
Power voltage   24 VDC  +10% / -15% 
Power consumption  8.2 W   
 
10.4  Environmental Effects 
10.4.1  Environmental Conditions 
Temperature range   
  Reference temperature  23 °C 
  Ambient temperature operation  -10... +55 °C  
  Switch-on temperature  0... +55 °C 
  Storage/ transport  -40... +70 °C 
Humidity  <95 %, without condensation, (acc. to IEC 68-2) 
Protection type  IP 20 
Vibration  to IEC 68-2-6, test Fc